TIP-0416-26, Best Practice for Recovery Boiler Inspection (Optimizing the Inspection Scope), 2015 PEERS Conference
ARE YOU A TAPPI MEMBER?
TAPPI members have exclusive, FREE access to technical conference papers and presentations six months after the conference in TAPPI's e-library. The e-Library offers:
- Unlimited access to more than 18,000+ documents
- Fast, robust search engine for fast search results
- Members get FREE access to conference proceedings, TAPPI JOURNAL articles, Paper360º articles, archived Solutions! articles, and much more
- View thousands of technical paper abstracts
- Ability to search by keyword, title, author, events or industry segment
*Technical papers and presentations are available for sale immediately following the conferences before the 6 month embargo period.
TIP 0416-26 describes a modern process for systematically designing a cost-effective inspection plan for every part of a recovery boiler. Following the TIP’s guidance systematically focuses inspections where damage mechanisms occur, and eliminates them where there is no damage mechanism. Match the inspection and NDT method to the damage mechanisms, and the likelihood of finding and accurately quantifying the damage is greatly increased. In short, look in areas where we know problems occur, and refrain from looking where damage does not or cannot happen. This reduces outage time and cost, and can allow longer intervals between outages.