Press Section Water Balance Testing, 2001 Engineering / Finishing & Converting Conference Proceedings
P. Worford--Monitoring and understanding of key parameters in the press section are essential to being able to establish
best practices for maximizing machine operating performance. Having equipment and methods in place to
obtain accurate information regarding water removal in the press section (including dewatering through
press nips and uhle boxes) allows for a means to establish optimal operational standards and pin point areas
requiring improvements. Measurement of water removal through properly designed and installed weir
boxes, supplemented by means of measuring shower water supply with rotometers, assists in providing
accurate information necessary to perform water balance testing in the press section. This paper discusses
the approach and method implemented to establish a monitoring program that is used to determine the
impact of varying press nip loadings, and press shower flows/pressures on press section water removal.
Modification to seal pit weir boxes provided a means to conduct accurate, on-line, water- removal and
water balance studies by individual positions within the press section.